Access Control · AC62
AC62 16 Door Controller
The **Verkada AC62** is a cloud-managed, enterprise-scale door controller designed for large deployments, supporting up to 16 doors, two AUX devices and a fire alarm interface (FAI) from a single unit.
SKU AC62-HW
Total MSRP$6,598
Hardware $5,999 + 1 door license (3-yr) $599
Door license term
Doors connected
1of 16 · one door license each
Hardware$5,999
Door license · 3-yr × 1$599
Total MSRP$6,598
Authorized Verkada reseller · cloud licensing configured at checkout
Overview
The Verkada AC62 is a cloud-managed, enterprise-scale door controller designed for large deployments, supporting up to 16 doors, two AUX devices and a fire alarm interface (FAI) from a single unit.
- Manages up to 16 doors, door accessories and fire alarm integrations from one cloud-managed controller
- Each door port supports two REX inputs, a DPI input and a reader port for native in/out door support
- Supports 12V/24V wet or dry locks: one 12V 1A or one 24V 0.5A wet relay per door, or one 24VDC 2A dry relay per door
- Fire alarm integration removes power from maglocks during a fire alarm for faster egress and firefighter access
- Connects to Verkada Command via Ethernet; on-device storage, compute and auxiliary battery support keep doors secured regardless of power or Internet status
- Natively connects with Verkada/RS-485 readers plus a Wiegand port per door for third-party readers
- Enterprise-scale terminal block design with multi-part structure, removable connectors and cable management loops; 10-year warranty
Specifications
- Doors
- Up to 16 doors, plus 2 AUX devices and a fire alarm interface (FAI)
- Power consumption
- 350W Maximum
- AC power input
- 100-240VAC, 50-60Hz
- Connectivity
- Ethernet: 100/1000Mbps RJ-45 for network connection; USB 2.0
- Door reader ports
- 1x Verkada/RS-485 per door (16 total); 1x Wiegand port per door (16 total)
- AUX reader ports
- 2x auxiliary reader ports (Verkada/RS-485) total
- Reader current consumption
- Door reader must be < 250mA per reader. Note: a max of 16 readers can be powered simultaneously
- Reader/relay power output
- 2x 12V @ 1A output; 2x 24V @ 0.5A output
- Relay outputs
- 1x wet or dry relay per door. Wet relay switch-selectable power: 12V operation 1A max, 24V operation 0.5A max. Dry relay max pass-through power: 24VDC @ 2A (resistive load). 2x auxiliary dry relays
- Inputs
- 2x REX dry inputs per door; 1x DPI dry input per door; 2x auxiliary dry inputs
- Compliance & safety
- FCC Part 15 Class B, ICES-3 Class B, CE, UKCA, RCM, VCCI, UL 294, CAN/ULC 60839-11-1, UL 62368-1, CSA C22.2 No. 62368-1, IEC 62368-1, NDAA
- Availability
- USA, CAN, IN, UK, EU
- Dimensions
- Length: 30.0in / 773.0mm; Width: 20.0in / 499.0mm; Height: 7.0in / 186.0mm
- Weight
- 20.0kg / 44lb
- Operating temperature
- 32°F - 122°F / 0°C - 50°C, 5 - 90% humidity
- Mounting options
- Mounting plate and 6 screws (#12x1")
- Included accessories
- Lock key and flat head screwdriver
- Warranty
- 10 years